From a sensor signal
to a wave estimate.
An instrument records a physical quantity: distance, pressure, acceleration or position. Turning that signal into wave height, period and direction requires a measurement model as well as careful processing. A smooth record is not necessarily an accurate record, and a precise sensor can still miss part of the wave spectrum.
Choose the quantity before the instrument.
A fixed surface gauge measures the changing elevation at one location. A submerged pressure sensor measures pressure fluctuations that depend on both the surface motion and the sensor's depth. A wave buoy measures its own motion, which follows the surface only within the limits of its mechanical and electronic response.
The required frequency band matters. An instrument and processing chain suitable for sea and swell may suppress the slower infragravity and seiche motions in Chapter 26 and Chapter 27. Record length, calibration, sampling and the site all need to match the question being asked.
One elevation record does not reveal direction.
A single elevation record supports a frequency spectrum and wave-by-wave statistics. It cannot uniquely determine the directional distribution. Directional observations need additional information, such as suitably spaced sensors or multiple buoy-motion components with a known orientation.
Reported directions also require a convention. This website uses clockwise angles from north describing propagation toward. When a data provider reports where waves come from, convert explicitly: θtoward = (θfrom + 180°) modulo 360°. Instrument axes and magnetic versus true north must be resolved before comparing observations.
| Instrument | Measured quantity | Important checks |
|---|---|---|
| Resistance or capacitance gauge | Water contact along a fixed probe, calibrated to elevation | Calibration, wetting, fouling, mounting disturbance and measurement range |
| Downward-looking radar or acoustic gauge | Distance to the surface from a reference position | Footprint, obstructions, spray, loss of returns and reference-platform motion |
| Submerged pressure sensor | Total or gauge pressure at a known submerged elevation | Atmospheric reference, density, depth, frequency-dependent pressure response and noise |
| Wave buoy | Motion inferred from accelerometers, attitude sensors or positioning signals, depending on the system | Hull and mooring response, orientation, processing filters and the supported frequency band |
What reaches a submerged pressure sensor?
A small, regular wave has surface amplitude a = 0.30 m (height H = 0.60 m). Move the sensor, change the depth or change the period. The same linear-wave solution generates the diagram, record and response curve. The pressure record below is noise-free; the separate noise calculation illustrates the sensitivity of the inverse correction.
z = 0 is the mean surface; the bed is z = −h. Sensor height above the bed is b, so zs = b − h. The wave outline is schematic.
Blue: surface elevation η. Coral: pressure-equivalent elevation p′/(ρg). This is wave-induced pressure after removal of atmospheric and mean hydrostatic contributions.
Navy: Kp. Coral dot: selected wave. The vertical axis is logarithmic. Shading below Kp = 0.10 marks the demonstration's excluded inversion range; it is not a universal field cutoff.
ρ = 1025 kg/m³; g = 9.81 m/s². Noise is a prescribed RMS pressure in a narrow band around the chosen frequency, not a sensor specification or a generated random time series. Fixed scales support direct comparisons.
Try the measurement before trusting the correction.
- Shorten the period while keeping depth and sensor position fixed. The pressure amplitude falls more strongly than the surface amplitude. The surface wave has not lost energy; the instrument is observing a different quantity below the surface.
- Raise the sensor toward the surface. Kp increases and the required inverse gain decreases. The pressure-response benefit must be balanced against practical exposure, mounting and possible emergence, which are not simulated.
- Increase the prescribed pressure noise. The clean records do not change, but the corrected noise rises. Dividing by a small Kp amplifies the desired signal and the noise together; it does not improve their signal-to-noise ratio at that frequency.
A transparent reference calculation.
For h = 10 m, b = 1 m and T = 8 s, solve (2π/T)² = gk tanh(kh) for k. This gives k ≈ 0.08862 m⁻¹ and Kp ≈ 0.70745. A 0.30 m surface amplitude produces about 0.21224 m of pressure-equivalent amplitude, or 2134 Pa of wave-pressure amplitude. The inverse amplitude gain is about 1.4135.
Surface variance is a²/2 = 0.045 m². Pressure-equivalent variance is Kp²a²/2 ≈ 0.02252 m². Recovering the surface variance requires division by Kp², not Kp. For 10 Pa RMS noise concentrated around this frequency, the equivalent surface-noise RMS is about 0.001406 m after correction. These are idealized linear calculations, not a claim about a particular instrument's accuracy.
Sampling and processing are part of the instrument.
A sample rate fs has a Nyquist frequency fs/2. An analogue or instrument-level anti-alias response is needed before sampling; a later digital filter cannot recover frequencies already folded into the record. A record of duration D has Fourier-bin spacing 1/D, while windowing and averaging affect the ability to distinguish peaks and the uncertainty of estimated spectral density. Chapter 10 develops these distinctions.
Keep the raw observations and document units, timestamps, sensor elevation, water depth, calibration and processing settings. Inspect spikes, missing samples, clipping, drift, motion of the mounting platform and changes in operating conditions. Removing a mean or trend can be appropriate, but an aggressive high-pass filter may also remove a real long-period signal.
For a 100 s oscillation, a 20-minute record contains only 12 cycles. A four-second wave contributes 300 cycles over the same duration. Neither count alone specifies uncertainty, but the contrast explains why slow processes require a different observation strategy. Avoid filling long gaps with smooth interpolation and then treating the result as measured wave information.
Pressure transfer, spectra and inverse-noise amplification
Take z positive upward from mean water level, h > 0 and 0 ≤ b ≤ h. For a fixed sensor at zs = b − h, linear theory gives the wave-pressure departure p′ from the mean hydrostatic state. The experiment assumes a uniform-depth, nonbreaking, small-amplitude wave with no ambient flow.
Kp is dimensionless and positive: Kp = 1 at the mean surface, and Kp = 1/cosh(kh) at the bed. As frequency approaches zero, Kp approaches one. Sq and Sη have units m²/Hz; Sp′ has units Pa²/Hz. The pressure transfer represents a depth-dependent response, not dissipation of wave energy.
For additive pressure noise uncorrelated with the wave signal, the estimated surface spectrum contains the true surface spectrum plus the noise spectrum divided by (ρgKp)². Inverting the response alone cannot distinguish them. Broadband noise must be treated frequency by frequency and integrated across the retained band; the single-band RMS calculation here is not a broadband correction.
The demonstration reports corrected signal amplitude only when Kp ≥ 0.10. This illustrative cap of ten on amplitude gain is not an accepted universal quality standard. A practical cutoff depends on noise, calibration, depth uncertainty, signal strength and the purpose of the measurement. Frequencies discarded as unreliable contain unknown wave variance; replacing them by zero is a processing choice, not proof that no waves exist there.
Buoy response and the limits of directional reconstruction
In an ideal heave measurement, vertical acceleration and displacement Fourier coefficients obey âz = −ω²η̂. Consequently Saz = ω⁴Sη and the inverse displacement spectrum divides by ω⁴. The negative sign describes a 180° phase difference; it disappears in the spectrum. Low-frequency errors become especially important when integrating acceleration, so orientation correction and well-characterized filtering are essential. This ideal identity is not a complete transfer function for any buoy.
Real hulls, moorings and electronics have frequency-dependent responses. Position-based and acceleration-based systems therefore need their own calibration and processing descriptions; an arbitrary generic buoy correction should not be applied to all observations.
Directional estimates from multiple motion components or arrays provide finite directional information. Reconstructing a smooth directional spectrum requires assumptions and does not uniquely reveal every crossing-wave component. Check array geometry, timing, compass alignment and the provider's conventions. Compare data and models over compatible frequency bands and averaging periods, as discussed in Chapter 21.